TEKLEEN® is proud to introduce its new line of fully automatic, self-cleaning water filters with working pressure as low as 15 psi - the Low Pressure Filter (LPF) Series. They are available in a wide range of industrial configurations and are designed and manufactured in accordance to ANSI and ASME standards. ASME U stamp is an option. Sizes range from 2" - 36", flow rates from 100 - 20,000 gpm, screen mesh from 10µ - 3,000µ.
The filters are available in stainless steel, carbon steel with powder epoxy coating and titanium. Clean filter pressure drop with 100µ screen is less than 1 psi at the rated flow of the filter.
Let us know what your filtration needs are and we'll design the best solution for the job.
Fill out an Application Datasheet to begin.
Filter Model | Flange Size (in) |
Screen Area (sq ft) |
Max Flow (gpm) |
Empty Weight (lbs) |
Cut Sheet | Installation Layout |
---|---|---|---|---|---|---|
LPF2-LP | 2.0 | 0.5 | 130.0 | 120.0 | DWG | PDF | DWG | PDF |
LPF2-SP | 2.0 | 1.4 | 200.0 | 150.0 | DWG | PDF | DWG | PDF |
LPF2-XLP | 2.0 | 2.5 | 250.0 | 180.0 | DWG | PDF | DWG | PDF |
LPF3-LP | 3.0 | 2.5 | 300.0 | 250.0 | DWG | PDF | DWG | PDF |
LPF3-SP | 3.0 | 1.4 | 200.0 | 150.0 | DWG | PDF | DWG | PDF |
LPF3-XLP | 3.0 | 5.0 | 400.0 | 280.0 | DWG | PDF | DWG | PDF |
LPF4-LP | 4.0 | 5.0 | 600.0 | 280.0 | DWG | PDF | DWG | PDF |
LPF4-LPE | 4.0 | 2.5 | 400.0 | 250.0 | DWG | PDF | DWG | PDF |
LPF4-P | 4.0 | 1.4 | 300.0 | 200.0 | DWG | PDF | DWG | PDF |
LPF4-XLP | 4.0 | 8.0 | 800.0 | 325.0 | DWG | PDF | DWG | PDF |
LPF6-LP | 6.0 | 5.0 | 800.0 | 300.0 | DWG | PDF | DWG | PDF |
LPF6-P | 6.0 | 2.5 | 600.0 | 260.0 | DWG | PDF | DWG | PDF |
LPF6-SP | 6.0 | 7.0 | 1750.0 | 535.0 | DWG | PDF | DWG | PDF |
LPF6-XLP | 6.0 | 8.0 | 800.0 | 335.0 | DWG | PDF | DWG | PDF |
LPF8-LP | 8.0 | 8.0 | 1500.0 | 360.0 | DWG | PDF | DWG | PDF |
LPF8-P | 8.0 | 5.0 | 1320.0 | 340.0 | DWG | PDF | DWG | PDF |
LPF8-SLP | 8.0 | 11.0 | 2500.0 | 620.0 | DWG | PDF | DWG | PDF |
LPF8-SP | 8.0 | 7.0 | 1750.0 | 560.0 | DWG | PDF | DWG | PDF |
LPF8-TLP | 8.0 | 16.0 | 2500.0 | 1000.0 | DWG | PDF | DWG | PDF |
LPF10-LP | 10.0 | 11.0 | 2630.0 | 650.0 | DWG | PDF | DWG | PDF |
LPF10-P | 10.0 | 7.0 | 1750.0 | 585.0 | DWG | PDF | DWG | PDF |
LPF10-SLP | 10.0 | 12.5 | 4000.0 | 825.0 | DWG | PDF | DWG | PDF |
LPF10-XLP | 10.0 | 16.0 | 6000.0 | 1300.0 | DWG | PDF | DWG | PDF |
LPF12-LP | 12.0 | 12.5 | 4000.0 | 850.0 | DWG | PDF | DWG | PDF |
LPF12-P | 12.0 | 11.0 | 2630.0 | 690.0 | DWG | PDF | DWG | PDF |
LPF12-TP | 12.0 | 22.0 | 3000.0 | 1500.0 | DWG | PDF | DWG | PDF |
LPF12-XLP | 12.0 | 16.0 | 6000.0 | 1300.0 | DWG | PDF | DWG | PDF |
LPF14-LP | 14.0 | 16.0 | 6000.0 | 1350.0 | DWG | PDF | DWG | PDF |
LPF14-P | 14.0 | 12.5 | 4000.0 | 900.0 | DWG | PDF | DWG | PDF |
LPF14-TLP | 14.0 | 32.0 | 12000.0 | 3000.0 | DWG | PDF | DWG | PDF |
LPF16-LP | 16.0 | 16.0 | 6000.0 | 1400.0 | DWG | PDF | DWG | PDF |
LPF16-P | 16.0 | 12.5 | 5000.0 | 925.0 | DWG | PDF | DWG | PDF |
LPF16-SP | 16.0 | 24.0 | 10000.0 | 2500.0 | DWG | PDF | DWG | PDF |
LPF16-TLP | 16.0 | 32.0 | 12000.0 | 3000.0 | DWG | PDF | DWG | PDF |
LPF16-TRLP | 16.0 | 48.0 | 18000.0 | 4500.0 | DWG | PDF | |
LPF18-LP | 18.0 | 16.0 | 6000.0 | 1450.0 | DWG | PDF | DWG | PDF |
LPF18-SP | 18.0 | 24.0 | 10000.0 | 1500.0 | DWG | PDF | DWG | PDF |
LPF20-SP | 20.0 | 24.0 | 10000.0 | 2500.0 | DWG | PDF | DWG | PDF |
LPF24-SP | 24.0 | 24.0 | 10000.0 | 2500.0 | DWG | PDF | DWG | PDF |
LPF24-TLP | 24.0 | 32.0 | 12000.0 | 3000.0 | DWG | PDF | DWG | PDF |
File Download | Document Title | Document Type |
---|---|---|
LPF Series Manual | Manual | |
PDF | DWG | Generic LPF Material of Construction | Material of Construction |
PDF | DWG | Piston Assembly 1.5" & 2" Indicator | Assembly |
PDF | DWG | Piston Assembly 1.5" & 2" Short | Assembly |
PDF | DWG | Piston Assembly 1.5" Indicator - Overall Dimensions | Assembly |
PDF | DWG | LPF-GB6 Wiring | Wiring Diagram |
PDF | DWG | LPF-GB7 Wiring | Wiring Diagram |
PDF | DWG | LPF Filter Installation Layout | Installation Layout |
PDF | DWG | LPF Filter Installation Layout with Wiring | Installation Layout |
PDF | DWG | LPF Filter with Electric Pressure Sustaining Valve | Installation Layout |
PDF | DWG | LPF Filter with Pneumatic Pressure Sustaining Valve | Installation Layout |
PDF | DWG | LPF Filter with Electric Bypass Valve | Installation Layout |
PDF | DWG | LPF Filter with Pneumatic Bypass Valve | Installation Layout |
PDF | DWG | LPF Filter with Electric Bypass & Pressure Sustaining Valves | Installation Layout |
PDF | DWG | LPF Filter with Pneumatic Bypass & Pressure Sustaining Valves | Installation Layout |
PDF | DWG | LPF Filter with Dewatering Bag | Installation Layout |
PDF | DWG | LPF Filter with Electric Bypass Valve & Dewatering Bag | Installation Layout |
PDF | DWG | LPF Filter with Piston Tank | Installation Layout |
PDF | DWG | 2 LPF Filters in Parallel | Installation Layout |
PDF | DWG | 2 LPF Filters in Parallel with Electric Bypass Valve | Installation Layout |
PDF | DWG | 2 LPF Filters in Parallel with Electric Pressure Sustaining Valve | Installation Layout |
PDF | DWG | 2 LPF Filters in Parallel with Electric Alarm Standby Filter | Installation Layout |
PDF | DWG | 3 LPF Filters in Parallel | Installation Layout |
PDF | DWG | 3 LPF Filters in Parallel with Electric Bypass Valve | Installation Layout |
PDF | DWG | 3 LPF Filters in Parallel with Electric Pressure Sustaining Valve | Installation Layout |
PDF | DWG | 3 LPF Filters in Parallel with Electric Pressure Sustaining & Bypass Valves | Installation Layout |
PDF | DWG | 4 LPF Filters in Parallel with Electric Bypass Valve | Installation Layout |
2672 S. La Cienega Blvd.
Los Angeles, CA 90034
Voice: (310) 839-2828
Fax: (310) 839-6878
Copyright © 2024 Automatic Filters, Inc. All Rights Reserved. Privacy policy.